Large electric motors create high amperage draws on rural
electrical systems, especially upon start-up. This spike can dim lights and
interfere with electronic equipment usage. Local electrical suppliers must charge
for the demand created by large motors as well as for the electrical energy
consumption. The high demand on start-up, even though it is momentary, may
generate additional charges from the electrical supplier. Electricity is in
high demand in summer months for residential and business cooling. Large motor
use during these months, especially in the evening, may incur additional
charges.
Because of the high amperage draw on start-up, utilities
limit electric motor horsepower on a single-phase power supply. The high cost
of running three-phase power to a large electric motor has caused many
irrigation pumps to be located along a highway where three-phase power is usually
available. Some utilities require “soft-start” controls which decrease the
spike in amperage on start-up. Variable Frequency Drives (VFDs) allow motors to
start under load at a slow speed and build speed slowly, thus minimizing the
amperage spike. This also makes it easier to use poly tubing for furrow or
flood irrigation by running at low speed until the holes are punched and the
tube is full of water. VFDs also allow the motor to run at an intermediate
speed and to slow down rather than stopping suddenly. VFDs can be used to
provide power to large motors from a single-phase power supplies. Current costs
for a VFD are about $100/horsepower.
Most irrigation pumps in Louisiana are driven by diesel
engines. The energy efficiency of an electric motor is much higher than that of
a diesel engine. Since no gear box is required, the overall efficiency of an
electric motor-driven well pump is even higher. Maintenance cost for an
electric motor is much less than for a diesel engine.
Following comparisons were provided by Phil Tacker,
Extension Irrigation Engineer (retired), University of Arkansas: Average of observed
energy efficiencies of power sources and calculated fuel energy consumption to
pull a 50 HP load, where Hp-Hr is horsepower-hours, Gal is gallons, CCF is 100
cubic feet, and KWH is kilowatt-hour:
Fuel/Energy Source
|
Efficiency average
|
50 Hp Load
|
Diesel
|
18.5 Hp-Hr/Gal
|
2.7 gal/hr
|
Natural Gas
|
10 Hp-Hr/CCF
|
5.0 ccf/hr
|
Propane
|
10 Hp-Hr/Gal
|
5.0 gal/hr
|
Gasoline
|
12 Hp-Hr/Gal
|
4.2 gal/hr
|
Electric Line-shaft
|
1.15 Hp-Hr/KWH
|
43.5 KWH.hr
|
Electric-Submersible
|
1.05 Hp-Hr/KWH
|
47.6 KWH/hr
|
To compare hourly costs for fuel/energy in pulling a 50 HP load,
multiply your expected fuel cost/gallon (or ccf for natural gas or KWH for
electricity) times the amount of fuel or energy used per hour. For example, a
diesel engine burning 2.7 gallons of fuel per hour at $3 per gallon of fuel
will have a fuel cost or $8.10 per hour of operation pulling a 50 HP load. The
cost for routine maintenance will be 15% of the fuel cost, or $1.22, for a
total operating cost of $9.32 per hour. An electric line-shaft motor pulling
the same 50 HP load with electricity at $0.10 per Kwh will have an energy cost
of $4.35 per hour plus a maintenance cost of $0.13 per hour for a total
operating cost of $4.48 per hour.
Source of fuel/energy
|
50 HP load fuel/energy use/hour
|
Unit cost $/gal, $/ccf, or $/Kwh
|
Energy cost per hour
|
Maintenance cost/hour as % of energy
cost/hour
|
Maint cost per hour
|
Total cost per hour
|
Diesel
|
2.7 gal
|
15 %
|
||||
Natural gas
|
5.0 ccf
|
12.5 %
|
||||
LPG
|
5.0 gal
|
12.5 %
|
||||
Gasoline
|
4.2 gal
|
15 %
|
||||
Elec-line shaft
|
43.5 Kwh
|
3 %
|
||||
Elec-submer
|
47.6 Kwh
|
6.5 %
|
Motor use in pumping water for rice irrigation occurs
earlier in the year and may not interfere as much with high summer time demand
for electricity, whereas cotton, corn and soybean irrigation typically occurs
during hot, dry summer months. Time-of-day charges have been implemented in
some parts of the United States. If irrigation can be avoided in the afternoon
and early evening hours, electric rates may be reduced. Growers have to weigh
the cost of potential crop yield loss if fields cannot be irrigated on time, if
they are to take advantage of time-of-day rate reductions.
When considering installing a large electric motor or
converting from a diesel engine to an electric motor, be sure to spend time
with your electricity supplier. Find out which rate schedule will be used for
charges. Is three-phase power available? If not, what is the cost for getting a
three-phase supply? Does the supplier offer a long-term contract to spread the
initial cost out over several years? Does the supplier require a soft start or
a variable frequency drive? What are the charges for transformers? Are there
extra charges for use in summer months? Are there time-of-day charges? Talk to
your electrical contractor, motor supplier or well driller. How much horsepower
does your irrigation supplier recommend? The HP required for an electric motor
will usually be less than for a diesel engine. How can you fit the motor into
the electrical supplier’s rate schedules? What adjustments can be made to
insure reasonable initial and operating costs?